KFAS: Fanuc Parts & Repair   

       

Fanuc A06B-6090-H244 replaces A06B-6066-H244

A06B-6090-H244 SVUC 2-40/40

A06B-6090-H244

$1,650 (Exchange Credit Available)   

SAME DAY SHIPPING: IF ORDERED BY 3PM CENTRAL TIME

Select Desire Shipping Option
Your UPS Account# & Method

* $400 Credit available for the 6090 repair exchange. NO CREDIT for 6066 units.

Repair/ Return Option for 6090-H244 Available At $1080.

Rated Input: 200~230 VAC 17A at 200V

Rated Output Current: L axis: 8.7A, L axis: 8.7A

A06B6090H244 B65192E Manual

Related technical information

Installation Guide    Video-1    Video-2

A06b-6090-H244

A06B-6090-H244

A06B-6090-H244

A06B-6090-H244 Alarms Meaning and action to be taken

Alarm     Meaning
1            Over Voltage Alarm (HV) 
2            Low Control Voltage Alarm (LV)
3            Low DC Link Voltage Alarm (LVDC)
4            Regenerative Control Circuit Alarm (DCSW)
5            Over Regenerative Discharge Alarm (DCOH) 
7            Dynamic brake Circuit Failure Alarm (DBRLY)
8            L-Axis Over current Alarm (HCL)
9            M-Axis Over current Alarm (HCM)
8.           L-Axis IPM Alarm (IPML)
9.           M-Axis IPM Alarm (IPMM)
b            L & M Axes Over Current 
b.           L & M Axes IPM Alarm

AL-2 or Alarm 2 Troubleshooting Steps for A06B-6066-H244
If the Alarm 2 occurs at power on (as opposed to while the machine is in operation) and the alarm can be reset after warm-up, the problem is most likely the servo amplifier.

Related Part NumbersKFASLLC kfasllc.com
A50L-0001-0266/N
A20B-2002-0032
A20B-2002-0157
A230-0450-T102