KFAS: Fanuc CNC Parts, Service, & Repair
Fanuc
SPINDLE ALARM 03
Spindle alarm AL-03 is
generated by Fanuc SPM or Spindle Amplifier.
AL-03 Fuse on DC Link Blown(SPM is faulty)
Steps to be taken to diagnose Alarm 03:
Check if the AL-03 is coming
on at spindle command.
Spindle Amplifier Module (SPM)
*CAUTION: High Voltage present.
Note: Some
Machine's electrical cabinet doors are equipped with "door interlock"
that will cause the breaker to trip when the door is open.
See the machine's manual for information on how to bypass so that you can observe the alarm LED status
Fanuc CNC Alarm App for your smart phone
© Copyright 2024 KFASLLC Houston, Texas, USA