A06B-6088-H255
SPM-55
A06B-6088-H255#H500 A06B-6088-H255#H501
*IMPORTANT: Please specify #H500 or #H501 when ordering.
This specify the internal spindle software.
SAME DAY SHIPPING: IF ORDERED BY 3PM CENTRAL TIME
Repair/ Return Option Also Available At $1750.
Rated INPUT: 283-325VDC 56.0kW
Maximum OUTPUT: 230VAC 198A
Spindle Amplifier Module A06B-6088-H245#H500 or A06B-6088-H245#H501 is used with spindle motor Alpha30 and Alpha40
Dimension: (W x H x D): 300mm x 380mm x 307mm
Related technical information View Picture
A06B-6088-H255 Alpha Series Spindle Amplifier Module is equipped with Internal cooling fan A90L-0001-0422
A06B-6088-H245 Alarms Meaning and action to be taken
Alarm Fault
– Not Ready(Not an alarm)
0 Control Ready(Not an alarm)
1 Motor overheat
2 Excessive Speed Error
3 Fuse on DC Link Blown(SPM is faulty)
4 Input Fuse/Power Fault(PSM is faulty)
5 Power Supply Fuse Blown
7 Overspeed
8 High Voltage Power Input
9 Overheat Main CIrcuit(SPM is faulty)
10 Low Voltage Input Power(Check input power)
11 Overvoltage in Power Circuit(PSM is faulty)
12
Overcurrent in Power Circuit
13 Data Memory Fault CPU(SPM is
faulty)
15
SP Switch Control Alarm
16 RAM Fault(SPM is faulty)
18 Sumcheck Error PGM Data
19
EX Offset Current U
20
EX Offset Current V
24 Serial Transfer Error(normal
if CNC is OFF)
25 Serial Transfer Stop
26 Disconnect C Velocity Detect
27 Pulsecoder Disconnected
28 Disconnect C-Pos Detect
29 Short time overload
30 Overcurrent(PSM is faulty)
31 Motor Lock or V-Sig Lost
32 Ram Fault Serial LSI
33 Shortage Power Charge(PSM is faulty)
34 Parameter Setting Error
35 Ex Setting Gear Ratio
36 Overflow Error Counter
37 Speed Detect Par. Error
39 1-Rot Cs Signal Detect
40 No 1 Rot Cs Signal Detect
41 1-Rot Position Coder Error
42 No 1 Rot. Position Coder Detect
43 Disconnect PC for Dif SP Mod
44 Control Circuit (AD) Error
46 Screw 1-Rot Position Coder Alarm
47 Position Coder Signal Abnormal
49 High Conv. Diff. Speed
50 Spindle Control Over Speed
51 Low Voltage DC Link(PSM is faulty)
52 ITP Signal Abnormal 1
53 ITP Signal Abnormal 2
56 Inner Cooling Fan Stop
57 Ex Deceleration Power
58 Overload in PSM(PSM is faulty)
59 Cooling Fan Stopped in PSM(PSM is faulty)
66 Communication Alarm between Spindle and Amplifier
69 Safety Speed Exceeded
70 Abnormal Axis Data
71 Abnormal Safety Parameter
72 Motor Speed Mismatch
73 Motor Sensor Disconnected
74 CPU Test Alarm
75 CRC Test Alarm
76 Safety Function Not Executed
77 Axis Number Mismatch
78 Safety Parameter Mismatch
79 Abnormal Initial Test Operation
81 Motor Sensor one-rotation signal detection error
82 Motor Sensor one-rotation signal not detected
83 Motor Sensor Signal Error
84 Spindle Sensor Disconnected
85 Spindle Sensor one-rotation signal detection error
86 Spindle Sensor one-rotation signal not detected
87 Spindle Sensor Signal Error
88 Cooling Fan on the radiator stopped(SPM is faulty)
Related Part NumbersKFASLLC kfasllc.com
A20B-1007-0591
A20B-1006-0690
A20B-2002-0080
A16B-2203-0332
A16B-2202-0432
The FANUC A06B-6088-H255#H500 AC Spindle Amplifier Module SPM-55 is used with Model 55 / aP60 spindle motor.
As part of the A06B-6088 series of AC spindle drives, the FANUC A06B-6088-H255#H500 Alpha Spindle Module is similar to
FANUC Models A06B-6088-H255#H501 and A06B-6088-H255#500CS.
Choose KFASLLC for all of your FANUC part needs! We offer a wide selection of refurbished FANUC parts including FANUC drive modules like the A06B6088H255H500.
Check the details above for availability, core credit exchange, and repair options.
A06B-6088-H255 is part of Fanuc Alpha Series family with advanced features including
・High mechanical precision and low vibration making it possible to directly connect to the spindle achieving high mechanical precision and low
vibration (V3).
・Utilizes Power source regeneration technology to return regeneration energy of the motor to a power source. Compared with the resistor regeneration, power consumption is greatly reduced.
・Compact, reduced Wiring utilizing fiber optics communications and easy maintenance features such as ability to replace cooling fans without disassembling the unit.
・Center-through-coolant is available by direct connection with the spindle of a machining center.