Personal Computer Settings
4800 Baudrate
2 stop bits
ISO Code (ASCII)
Even parity
Data length = 7 bits
Control Codes (Xon/ Xoff used)
LF for End Of Block
RS 232 Parameters for Fanuc 16/ 18/21 controls
Note: The RS232 settings
are common for 16MA, 16TA, 16MB, 16TB, 16MC,
16TC, 16iMA,
16iTA, 18MA, 18TA, 18MB, 18TB, 18MC, 18TC, 18iMA, 18iTA,
21MB, 21TB,
21iTA, 21iMA controls
SETTING PAGE
ISO = 1 (0:EIA 1:ISO)
I/O = 0
PARAMETERS
0000 = XXXXXX10
0100 = 00000000
0102 = 0
0103 = 10 (baud rate)
X's denote data not related to RS232
Baud rate Setting on PRM 103
50
1
100
2
110 3
150 4
200 5
300 6
600 7
1200 8
2400 9
4800 10
9600 11