KFAS: Fanuc CNC Parts, Service, & Repair

      

       

Do you have a 6TA/ 6MA control?

Fanuc 6 control RS232 serial communication parameters

Personal Computer Settings
4800 Baudrate
2 stop bits
ISO Code (ASCII)
Even parity
Data length = 7 bits
Control Codes (Xon/ Xoff used)
LF for End Of Block

Fanuc 6-TB and 6-MB controls

SETTING PAGE
PUNCH CODE = 1 (0:EIA 1:ISO)
INPUT DEVICE 1 = 0 (0:TAPE 1:RMT)
INPUT DEVICE 2 = 1 (1:RS232C)

PARAMETERS
007 = 0XXXXXXX 6T
008 = 0XXXXXXX 6M
311 = 10011001
340 = 2
341 = 2

Set Parameter 311 according to the  following table  
Baud Rate 7 6 5 4 3 2 1 0
50 0 0 0 0 0 1 0 0
100 1 0 0 0 0 1 0 0
110 1 0 0 0 0 1 0 1
150 1 0 0 0 1 0 0 0
200 1 1 0 0 0 1 0 0
300 1 0 0 0 1 1 0 0
600 1 1 0 0 1 1 0 0
1200 1 1 0 0 1 1 1 0
2400 1 1 0 0 1 1 1 1
4800 1 1 1 0 1 1 1 1
9600 1 1 1 1 1 1 1 1

6T-B Maintenance Manual B-52245E

   

  © Copyright KFASLLC Houston, Texas, USA