SAME DAY SHIPPING: IF ORDERED BY 3PM CENTRAL TIME
Repair/ Return Option Also Available At $1400.
E-mail: service@kfasllc.com
$2,450 ($750 Exchange Credit Available)
Dimensions (H 380 x W 90 x D 307 mm)
Rated Input: 283-325VDC 3.1 kW
Rated Output Current: L axis 3.0A, M axis 5.9A, N axis 5.9A
Alarm 368 369 Note Alarm 466 Note
A06B-6096-H303 Alarms Meaning and action to be taken
Alarm Meaning
1
Internal Fan Stopped (FAL)
2
Low control power voltage (LV5V)
5
Low DC link voltage (LVDC)
8
L-axis over-current (HCL)
9
M-axis over-current (HCM)
A
N-axis over-current (HCN)
b L
& M-axis over-current
C M
& N-axis over-current
d L
& N-axis over-current
E
L, M, N -axis over-current
8.
L-axis IPM alarm (IPML)
9.
M-axis IPM alarm (IPMM)
A.
N-axis IPM alarm (IPMN)
b. L
& M-axis IPM alarm
C. M
& N-axis IPM alarm
d. L
& N-axis IPM alarm
E.
L, M, N-axis IPM alarm
L FSSB
Disconnect COP10A
U FSSB
Disconnect COP10B
Related Part NumbersKFASLLC kfasllc.com
A50L-0001-0304 and A50L-0001-0273/A
A20B-2100-0260A16B-2202-0782
A90L-0001-0385