KFAS: Fanuc Parts & Repair

A06B-6096-H116  SVM1-130S

Repair/ Return Option Also Available At $700. 

       

a06b6096h116

SAME DAY SHIPPING: IF ORDERED BY 3PM CENTRAL TIME

$1,700 ($600 Exchange Credit Available)   
Select Desire Shipping Option
Your UPS Account# IF COLLECT

E-mail:  service@kfasllc.com

A06B-6096-H116  SVM1-130S

Dimensions (H 380 x W 60 x D 307 mm)

Rated Input: 283-325VDC 7.5 kW

Rated Output Current: L axis    35 A

A06B6096H116 B65165E Manual

Related technical information

Alarm 368 369 Note    Alarm 466 Note

A06B-6096-H105 Alarms Meaning and action to be taken

Alarm     Meaning
1              Internal Fan Stopped (FAL)
2              Low control power voltage (LV5V)
5              Low DC link voltage (LVDC)
8              L-axis over-current (HCL)
9              M-axis over-current (HCM)
A              N-axis over-current (HCN) 
b             L & M-axis over-current
C             M & N-axis over-current
d             L & N-axis over-current
E              L, M, N -axis over-current
8.             L-axis IPM alarm (IPML)
9.             M-axis IPM alarm (IPMM)
A.             N-axis IPM alarm (IPMN) 
b.            L & M-axis IPM alarm
C.            M & N-axis IPM alarm
d.            L & N-axis IPM alarm
E.             L, M, N-axis IPM alarm
L            FSSB Disconnect COP10A
U            FSSB Disconnect COP10B