KFAS: Fanuc CNC Parts, Service, & Repair

         

   

Fanuc ALARM U Bi SVPM AL-U

Alarm U Status 2 of ßi SVPM means,
Inverter: FSSB communication error (COP10B)
Cause and troubleshooting 
(a) Replace the βi SVM optical cable (COP10B) that is nearest to the βi SVPM on which "U" is displayed 
(the cable between βi SVM No.3 and βi SVPM). 

(b) Replace the βi SVM that is nearest to the βi SVPM on which "U" is displayed 
(βi SVM No.3). 

(c) Replace the COP10B-side βi SVM that is nearest to the βi SVPM on which "U" is displayed 
(βi SVM No.2). 

(d) Replace the axis control card in the CNC. 

Fanuc Beta i SVPM Alarm U A06B-6134

Related Manual B-65325EN

*CAUTION: High Voltage present.
Note: Some Machine's electrical cabinet doors are equipped with "door interlock" that will cause the breaker to trip when the door is open.  
See the machine's manual for information on how to bypass so that you can observe the alarm LED status

   

Fanuc CNC Alarm App for your smart phone

  © Copyright KFASLLC Houston, Texas, USA