KFAS: Fanuc CNC Parts, Service, & Repair

         

   

Fanuc ALARM SV0443 SP9059 aiPS-B AL-02

Alarm SV0443 and SP9059 on Fanuc 0iF or 31iB and AL-02 on aiPS-B means,

Internal cooling fan of the Power Supply Module Alpha iPS-B is not operating properly.

Check the rotation of the internal cooling fan (located at the top side of the AiPS-B)
- Replace the cooling fan as necessary

alpha-iB cooling fan AL-02 SV0443 SP9059

 

- Replace the Power Supply Module if the problem continues to exist after replacing the fan.

A06B6200 aiPS-B B65515EN Maintenance Manual

*CAUTION: High Voltage present.
Note: Some Machine's electrical cabinet doors are equipped with "door interlock" that will cause the breaker to trip when the door is open.  
See the machine's manual for information on how to bypass so that you can observe the alarm LED status

This alarm is applicable for the following units

A06B-6200-H003 αiPS 3-B
A06B-6200-H008 αiPS 7.5-B
A06B-6200-H011 αiPS 11-B
A06B-6200-H015 αiPS 15-B
A06B-6200-H026 αiPS 26-B
A06B-6200-H030 αiPS 30-B
A06B-6200-H037 αiPS 37-B
A06B-6200-H055 αiPS 55-B

A06B-6202-H003 αiPS 3-B
A06B-6202-H008 αiPS 7.5-B
A06B-6202-H011 αiPS 11-B
A06B-6202-H015 αiPS 15-B
A06B-6202-H026 αiPS 26-B
A06B-6202-H030 αiPS 30-B
A06B-6202-H037 αiPS 37-B
A06B-6202-H055 αiPS 55-B

   

Fanuc CNC Alarm App for your smart phone

  © Copyright KFASLLC Houston, Texas, USA