KFAS: Fanuc CNC Parts, Service, & Repair
K Factory Automation Services has large inventory of Fanuc parts in stock and we maintain a full service in-house repair facility.
(1) Check the Diagnostic 202
DGN 203 | #7 DTE | #6 CRC | #5 STB | #4 | #3 | #2 | #1 | #0 |
#7
(DTE)
Data error has occurred.
Communication failure of serial pulse coder.
Check items: (1) Pulse coder
feedback cable is disconnected
(2) Serial pulse coder is faulty
(3) +5V supply
to the pulse coder is abnormally low.
#6 (CRC) CRC error has occurred. Serial Pulse Coder communication data is erroneous.
#5 (STB) Stop bit error has occurred. Serial Pulse Coder communication data is erroneous.
If
DGN 203 bit#5 (STB) and/or bit#6 (CRC) = 1,
Check items:
(1) Pulse coder
feedback cable is disconnected
(2) Serial pulse coder is faulty
(3) Main CPU
board or Option 2 board is faulty.
This alarm is applicable to Fanuc 18TB, 16MB, 18TC, 16MC, 18MC control
© Copyright KFASLLC Houston, Texas, USA