Program Errors /Alarms on program and operation (P/S alarm)
-
PS003 TOO MANY DIGIT
-
-
PS006 ILLEGAL USE OF MINUS SIGN
-
-
PS007 ILLEGAL USE OF DECIMAL POINT
-
-
PS010 IMPROPER G–CODE
-
-
PS011 IMPROPER NC–ADDRESS
-
-
PS012 INVALID BREAK POINT OF WORDS
-
-
PS013 ILLEGAL POS. OF PROGRAM NO.
-
-
PS014 ILLEGAL FORMAT OF PROGRAM NO.
-
-
PS015 TOO MANY WORD IN ONE BLOCK
-
-
PS016 EOB NOT FOUND
-
-
PS017 ILLEGAL MODE FOR GOTO/WHILE/DO
-
-
PS058 S–COMMAND OUT OF RANGE
-
-
PS059 COMMAND IN BUFFERING MODE
-
-
PS060 SEQUENCE NUMBER NOT FOUND
-
-
PS061 NO P, Q COMMAND AT G70–G72
-
-
PS062 ILL COMMAND IN G70–G76
-
-
PS063 P, Q BLOCK NOT FOUND
-
-
PS064 SHAPE PROGRAM NOT MONOTONOUS
-
-
PS065 ILL COMMAND IN P–BLOCK
-
-
PS066 ILL COMMAND IN PROGRAM
-
-
PS067 G70–G73 IN FORBIDDEN MODE
-
-
PS069 ILL COMMAND IN Q–BLOCK
-
-
PS076 PROGRAM NOT FOUND
-
-
PS077 PROGRAM IN USE
-
-
PS079 PROGRAM FILE NOT FOUND
-
-
PS090 DUPLICATE NC, MACRO STATEMENT
-
-
PS091 DUPLICATE SUB–CALL WORD
-
-
PS092 DUPLICATE MACRO–CALL WORD
-
-
PS093 DUPLICATE NC–WORD & M99
-
-
PS094 USE ’G’ AS ARGUMENT
-
-
PS095 TOO MANY TYPE–2 ARGUMENT
-
-
PS100 CANCEL WITHOUT MODAL CALL
-
-
PS110 OVERFLOW: INTEGER
-
-
PS111 OVERFLOW: FLOATING
-
-
PS112 ZERO DIVIDE
-
-
PS114 VARIABLE NO. OUT OF RANGE
-
-
PS115 READ PROTECTED VARIABLE
-
-
PS116 WRITE PROTECTED VARIABLE
-
-
PS118 TOO MANY BRACKET NESTING
-
-
PS119 ARGUMENT VALUE OUT OF RANGE
-
-
PS121 TOO MANY SUB,MACRO NESTING
-
-
PS122 TOO MANY MACRO NESTING
-
-
PS123 MISSING END STATEMENT
-
-
PS124 MISSING DO STATEMENT
-
-
PS125 ILLEGAL EXPRESSION FORMAT
-
-
PS126 ILLEGAL LOOP NUMBER
-
-
PS128 SEQUENCE NUMBER OUT OF RANGE
-
-
PS131 MISSING OPEN BRACKET
-
-
PS132 MISSING CLOSE BRACKET
-
-
PS133 MISSING ‘=’
-
-
PS134 MISSING ‘,’
-
-
PS135 MACRO STATEMENT FORMAT ERROR
-
-
PS136 DFA STATEMENT FORMAT ERROR
-
-
PS137 IF STATEMENT FORMAT ERROR
-
-
PS138 WHILE STATEMENT FORMAT ERROR
-
-
PS139 SETVN STATEMENT FORMAT ERROR
-
-
PS141 ILLEGAL CHARACTER IN VAR. NAME
-
-
PS142 TOO LONG V–NAME (SETVN)
-
-
PS143 BPRNT/DPRNT STATEMENT FORMAT ERROR
-
-
PS144 G10 FORMAT ERROR
-
-
PS145 G10.1 TIME OUT
-
-
PS146 G10.1 FORMAT ERROR
-
-
PS150 G31 FORMAT ERROR
-
-
PS180 ALL PARALLEL AXES IN PARKING
-
-
PS181 ZERO RETURN NOT FINISHED
-
-
PS182 CIRCLE CUT IN RAPID (F0)
-
-
PS183 TOO MANY SIMULTANEOUS AXES
-
-
PS184 TOO LARGE DISTANCE
-
-
PS185 ZERO RETURN CHECK (G27) ERROR
-
-
PS186 ILLEGAL PLANE SELECT
-
-
PS187 FEED ZERO (COMMAND)
-
-
PS188 PARAMETER ZERO (DRY RUN)
-
-
PS190 PARAMETER ZERO (CUT MAX)
-
-
PS191 OVER TOLERANCE OF RADIUS
-
-
PS192 ILLEGAL LEAD COMMAND (G34)
-
-
PS193 ILLEGAL OFFSET NUMBER
-
-
PS194 ZERO RETURN END NOT ON REF
-
-
PS195 ILLEGAL AXIS SELECTED (G96)
-
-
PS196 ILLEGAL DRILLING AXIS SELECTED
-
-
PS197 OTHER AXIS ARE COMMANDED
-
-
PS198 ILLEGAL INDEX ANGLE
-
-
PS199 ILLEGAL COMMAND IN INDEXING
-
-
PS200 PULSCODER INVALID ZERO RETURN
-
-
PS201 G02.1/03.1 FORMAT ERROR (M)
-
-
PS201 ILLEGAL LEAD COMMAND (G35) G02.1/03.1 (T)
-
-
PS205 TURRET REF. NOT FINISHED
-
-
PS206 ILLEGAL TOOL NO.
-
-
PS210 ILLEGAL WAITING M–CODE
-
-
PS211 PROGRAM NUMBER ODD/EVEN ERROR
-
-
PS212 ILLEGAL BALANCE CUTTING G–CODE
-
-
PS213 ILLEGAL USE OF G12.1/G13.1
-
-
PS214 ILLEGAL USE OF G–CODE
-
-
PS215 ILLEGAL COMMAND IN G10.6
-
-
PS217 ILLEGAL OFFSET VALUE
-
-
PS218 FORMAT ERROR
-
-
PS223 ILLEGAL SPINDLE SELECT
-
-
PS229 G10.7 FORMAT ERROR
-
-
PS270 CRC: START_UP /CANCEL BY CIRCLE
-
-
PS271 CRC: PLANE CHANGE
-
-
PS272 CRC: INTERFERENCE
-
-
PS280 ILLEGAL COMMAND IN SPIRAL
-
-
PS299 ILLEGAL ZERO RETURN COMMAND
-
-
PS300 ILLEGAL ADDRESS
-
-
PS301 MISSING ADDRESS
-
-
PS302 ILLEGAL DATA NUMBER
-
-
PS303 ILLEGAL AXIS NUMBER
-
-
PS304 TOO MANY DIGIT
-
-
PS305 DATA OUT OF RANGE
-
-
PS306 MISSING AXIS NUMBER
-
-
PS307 ILLEGAL USE OF MINUS SIGN
-
-
PS308 MISSING DATA
-
-
PS400 PROGRAM NOT MATCH
-
-
PS410 G37 IMPROPER AXIS COMMAND
-
-
PS411 G37 SPECIFIED WITH H CODE
-
-
PS412 G37 OFFSET NO. UNASSIGNED
-
-
PS413 G37 SPECIFIED WITH T–CODE
-
-
PS414 G37 OFFSET NO. UNASSIGNED
-
-
PS415 G37 MEASURING POSITION REACHED SIGNAL IS NOT PROPERLY INPUT
-
-
PS418 SPINDLE & OTHER AXIS MOVE
-
-
PS419 SPINDLE NOT ZERO RETURNED
-
-
PS421 SETTING COMMAND ERROR
-
-
PS422 NOT FOUND TOOL DATA
-
-
PS425 NOT DELETE TOOL DATA IN OPERATION
-
-
PS426 TOO MANY ADDRESSES
-
-
PS427 TOO MANY AXES FOR I–R MOVE
-
-
PS428 MISMATCH AXIS WITH CNR, CHF
-
-
PS429 MISSING VALUE AT CNR, CHF
-
-
PS430 CODE ISN’T G01 AFTER CNR, CHF
-
-
PS431 MISSING MOVE AFTER CNR, CHF
-
-
PS437 ILLEGAL LIFE GROUP NUMBER
-
-
PS438 GROUP NOT FOUND AT LIFE DATA
-
-
PS439 OVER MAXIMUM TOOL NUMBER
-
-
PS440 T COMMAND NOT FOUND
-
-
PS441 NOT USING TOOL IN LIFE GROUP
-
-
PS442 ILLEGAL T COMMAND AT M06
-
-
PS443 P, L COMMAND NOT FOUND
-
-
PS445 ILLEGAL L COMMAND
-
-
PS446 ILLEGAL H, D, T COMMAND
-
-
PS447 ILLEGAL TYPE OF TOOL CHANGE
-
-
PS448 ILLEGAL FORMAT AT LIFE DATA
-
-
PS449 ILLEGAL TOOL LIFE DATA
-
-
PS450 IN PMC AXIS MODE
-
-
PS533 ADDRESS F UNDERFLOW (G95)
-
-
PS573 EGB PARAMETER SETTING ERROR
-
-
PS574 EGB FORMAT ERRO
-
-
PS575 ILL–COMMAND IN EGB MODE
-
-
PS577 G80 FORMAT ERROR
-
-
PS578 G80 PARAMETER SETTING ERROR
-
-
PS580 ENCODE ALARM (PSWD&KEY)
-
-
PS581 ENCODE ALARM (PARAMETER)
-
-
PS585 G81 PARAMETER SETTING ERROR
-
-
PS586 G81 FORMAT ERROR
-
-
PS587 ILL–COMMAND IN G81 MODE
-
-
PS610 ILLEGAL G07.1 AXIS
-
-
PS611 ILLEGAL G–CODE USE (G07.1 MODE)
-
-
PS625 TOO MANY G68 NESTING
-
-
PS626 G68 FORMAT ERROR
-
-
PS630 HPCC:ILLEGAL START U/CANCEL
-
-
PS631 HPCC:NOT READY STATE
-
-
PS632 HPCC:ILLEGAL PARAMETER
-
-
PS633 HPCC:CRC OFS REMAIN AT CANCEL
-
-
PS634 HPCC:ILLEGAL COMMAND CODE
-
-
PS710 ILLEGAL COMMAND IN 3–D CIR
-
-
PS711 ILLEGAL COMBINATION OF M CODES
-
-
PS805 ILLEGAL COMMAND
-
-
PS891 ILLEGAL COMMAND G05
-
-
PS895 ILLEGAL PARAMETER IN G02.3/G03.3
-
-
PS896 ILLEGAL FORMAT IN G02.3/G03.3
-
-
PS897 ILLEGAL COMMAND IN G02.3/G03.3
-
-
PS898 ILLEGAL PARAMETER IN G54.2
-
-
PS900 G72.1 NESTING ERROR G72.1
-
-
PS901 G72.2 NESTING ERROR G72.2
-
-
PS920 ILL–COMMAND IN G05.1 Q1
-
-
PS935 ILLEGAL FORMAT IN G02.2/G03.2
-
-
PS936 ILLEGAL COMMAND IN G02.2/G03.2
-
-
PS937 OVER TOLERANCE OF END POINT
-
-
PS990 SPL: ILLEGAL AXIS COMMAND
-
-
PS991 SPL: ILLEGAL COMMAND
-
-
PS992 SPL: ILLEGAL AXIS MOVING
-
-
PS993 SPL: CAN’T MAKE VECTOR
-
-
PS994 SPL : ERROR
-
-
PS996 G41.3/G40 FORMAT ERROR
-
-
PS997 ILLEGAL COMMAND IN G41.3
-
-
PS998 G41.3 ILLEGAL START_UP
-
-
PS999 ILLEGAL PARAMETER IN G41.3
SR Alarms
-
SR160 COMMAND DATA OVERFLOW
-
-
SR310 H, S, C ERROR
-
-
SR311 H, S, C ERROR
-
-
SR312 H, S, C ERROR
-
-
SR313 H, S, C ERROR
-
-
SR314 H, S, C ERROR
-
-
SR315 H, S, C ERROR
-
-
SR316 H, S, C ERROR
-
-
SR317 H, S, C ERROR
-
-
SR318 H, S, C ERROR
-
-
SR319 H, S, C ERROR
-
-
SR320 H, S, C ERROR
-
-
SR424 OVER MAXIMUM TOOL DATA
-
-
SR590 TH ERROR
-
-
SR591 TV ERROR
-
-
SR592 END OF RECORD
-
-
SR600 PARAMETER OF RESTART ERROR
-
-
SR805 ILLEGAL COMMAND
-
-
SR806 DEVICE TYPE MISS MATCH
-
-
SR807 PARAMETER SETTING ERROR
-
-
SR810 PTR NOT READY
-
-
SR812 OVERRUN ERROR (PTR)
-
-
SR820 DR OFF (1)
-
-
SR 821 CD OFF(1)
-
-
SR822 OVERRUN ERROR (1)
-
-
SR823 FRAMING ERROR (1)
-
-
SR824 BUFFER OVERFLOW (1)
-
-
SR830 DR OFF (2)
-
-
SR831 CD OFF(2)
-
-
SR832 OVERRUN ERROR (2)
-
-
SR833 FRAMING ERROR (2)
-
-
SR834 BUFFER OVERFLOW (2)
-
-
SR840 DR OFF (3)
-
-
SR841 CD OFF(3)
-
-
SR842 OVERRUN ERROR (3)
-
-
SR843 FRAMING ERROR (3)
-
-
SR844 BUFFER OVERFLOW (3)
-
-
SR860 DR OFF (MODEM CARD)
-
-
SR861 CARRIER DETECT DOWN (ASR33/43)
-
-
SR862 OVERRUN ERROR (MODEM CARD)
-
-
SR863 FRAMING ERROR (MODEM CARD)
-
-
SR864 BUFFER OVERFLOW (MODEM CARD)
-
-
SR870 DATA SET READY DOWN (RS422)
-
-
SR872 OVERRUN ERROR (RS422)
-
-
SR873 FRAMING ERROR (RS422)
-
-
SR874 BUFFER OVERFLOW (RS422)
-
-
SR880 NOT DRAWING
-
-
SR890 CHECK SUM ERROR (G05)
Parameter Enable Switch Alarm (SW ALARM)
-
SW000 PARAMETER ENABLE SWITCH ON
Servo Alarm (SV ALARM)
-
SV000 TACHOGENERATER DISCONNECT
-
-
SV001 EXCESS CURRENT IN SERVO
-
-
SV002 BREAKER (FEED_CTL_UNIT) OFF
-
-
SV003 ABNORMAL CURRENT IN SERVO
-
-
SV004 EXCESS V TO MOTOR
-
-
SV005 EXCESS DISCHARGE I FROM MOTOR
-
-
SV006 VELOCTY UNIT POWER TOO LOW
-
-
SV008 EXCESS ERROR (STOP)
-
-
SV009 EXCESS ERROR (MOVING)
-
-
SV010 EXCESS DRIFT COMPENSATION
-
-
SV011 LSI OVERFLOW
-
-
SV012 MOTION VALUE OVERFLOW
-
-
SV013 IMPROPER V_READY OFF
-
-
SV014 IMPROPER V_READY ON
-
-
SV015 PULSE CODER DISCONNECTED
-
-
SV017 ILL POSITION CONTROL LSI
-
-
SV018 INCORRECT DSCG FREQUENCY
-
-
SV019 INCORRECT PULSE CODER PULSE
-
-
SV020 INCORRECT PHASE SHIFT VALUE
-
-
SV021 1–REV PULSE SIGNAL INCORRECT
-
-
SV022 1–REV PULSE MISSING
-
-
SV023 SV OVERLOAD
-
-
SV024 SYNC EXCESS ERROR ALARM 2
-
-
SV025 V_READY ON (INITIALIZING)
-
-
SV026 ILLEGAL AXIS ARRANGE
-
-
SV027 ILL DGTL SERVO PARAMETER
-
-
SV030 EMERGENCY STOP
-
-
SV031 EXCESS SPINDLE DIST (SPDL)
-
-
SV032 LSI OVERFLOW (SPDL)
-
-
SV050 ILLEGAL AXIS SYNCHRONIZATION
-
-
SV055 ILLEGAL TANDEM AXIS
-
-
SV056 ILLEGAL TANDEM PAIR
-
-
SV99 SPINDLE–AXIS ERROR
-
-
SV100 S–COMP. VALUE OVERFLOW
-
-
SV101 DATA ERROR (ABS PCDR)
-
-
SV110 PULSE CORDER ALARM (SERIAL A)
-
-
SV111 PULSE CORDER ALARM (SERIAL C)
-
-
SV114 ABNORMAL REV. DATA (SERIAL A)
-
-
SV115 ABNORMAL COMMUNICATION (SPLC)
-
-
SV116 MCC WELDING ARARM
-
-
SV117 ABNORMAL CURRENT OFFSET
-
-
SV118 DETECT ABNORMAL TORQUE
-
-
SV119 ABNORMAL TORQUE (1ST SPDL)
-
-
SV125 EXCESS VELOCITY IN TORQUE
-
-
SV126 EXCESS ERROR IN TORQUE
-
-
SV323 DISCONNECT ALARM BY SOFT
-
-
SV324 DISCONNECT ALARM BY HARD
-
-
SV325 PULSE CODER ALARM1 (SPLC)
-
-
SV326 PULSE CODER ALARM3 (SPLC)
-
-
SV327 ABNORMAL REV. DATA (SPLC)
-
-
SV330 ABNORMAL COMMUNICATION (SPLC)
-
-
SV331 PULSE CODER ALARM2 (SPLC)
-
-
SV333 PULSE CODER ALARM4 (EX–LIN)
-
-
SV335 ABNORMAL REV. DATA (EX–ROT)
-
-
SV336 BATTERY ZERO (EX)
-
-
SV338 DETECTOR OVER LOAD (EX)
-
-
SV339 ABNORMAL COMMUNICATION (EX)
-
-
SV340 PULSE CODER DISCONNECT (EX)
Overtravel Alarm (OT ALARM)
-
OT001 + OVERTRAVEL (SOFT 1)
-
-
OT002 – OVERTRAVEL (SOFT 1)
-
-
OT003 + OVERTRAVEL (SOFT 2)
-
-
OT004 – OVERTRAVEL (SOFT 2)
-
-
OT005 + OVERTRAVEL (SOFT3)
-
-
OT006 – OVERTRAVEL (SOFT3)
-
-
OT007 + OVERTRAVEL (HARD)
-
-
OT008 – OVERTRAVEL (HARD)
-
-
OT021 + OVERTRAVEL (PRE–CHECK)
-
-
OT022 – OVERTRAVEL (PRE–CHECK)
-
-
OT030 SYNC EXCESS ERROR ALARM 1
-
-
OT031 SYNCHRONIZE ADJUST MODE
-
-
OT032 NEED ZRN (ABS PCDR)
-
-
OT034 BATTERY ZERO (ABS PCDR)
-
-
OT036 BATTERY DOWN (ABS PCDR)
-
-
OT037 BATTERY DOWN (EX)
-
-
OT038 BATTERY ZERO (SPLC)
-
-
OT039 BATTERY ZERO (EX)
-
-
OT100 SPINDLE ALARM
-
-
OT101 SPINDLE MOTOR OVERHEAT
-
-
OT102 EXCESS VELOCITY ERROR
-
-
OT103 FUSE F7 BLEW
-
-
OT104 FUSE F1, F2 OR F3 BLEW
-
-
OT105 FUSE AF2 OR AF3 BLEW
-
-
OT106 EXCESS VELOCITY (ANALOG)
-
-
OT107 EXCESS VELOCITY (DIGITAL)
-
-
OT108 VOLTAGE (+24V) TOO HIGH
-
-
OT109 POWER SEMICONDUCTOR OVERLOAD
-
-
OT110 VOLTAGE (+15) TOO LOW
-
-
OT111 VOLTAGE EXCESS (DC LINK)
-
-
OT112 CURRENT EXCESS (DC LINK)
-
-
OT113 CPU ERROR
-
-
OT114 ROM ERROR
-
-
OT115 OPTION ALARM
-
-
OT116 DISCONNECTION POS CODER
-
-
OT117 SPINDLE OVERHEAT
-
-
OT120 UNASSIGNED ADDRESS (HIGH)
-
-
OT121 UNASSIGNED ADDRESS (LOW)
-
-
OT122 TOO MANY MESSAGE
-
-
OT123 MESSAGE NUMBER NOT FOUND
-
-
OT124 OUTPUT REQUEST ERROR
-
-
OT125 TOO LARGE NUMBER
-
-
OT126 SPECIFIED NUMBER NOT FOUND
-
-
OT127 DI. EIDHW OUT OF RANGE
-
-
OT128 DI. EIDLL OUT OF RANGE
-
-
OT129 NEGATE POS CODER 1 REV ON
-
-
OT130 SEARCH REQUEST NOT ACCEPTED
-
-
OT131 EXT–DATA ERROR (OTHER)
-
-
OT132 NOT ON RETURN_POINT
-
-
OT150 A/D CONVERT ALARM
-
-
OT151 A/D CONVERT ALARM
-
-
OT184 PARAMETER ERROR IN TORQUE
-
-
OT200 INTERFERENCE DATA ERROR
-
-
OT208 INTERFERENCE X1 MINUS
-
-
OT209 INTERFERENCE X1 PLUS
-
-
OT210 INTERFERENCE Z1 MINUS
-
-
OT211 INTERFERENCE Z1 PLUS
-
-
OT212 INTERFERENCE X2 MINUS
-
-
OT213 INTERFERENCE X2 PLUS
-
-
OT214 INTERFERENCE Z2 MINUS
-
-
OT215 INTERFERENCE Z2 PLUS
-
-
OT300 S–SPINDLE LSI ERROR
-
-
OT301 MOTOR OVERHEAT
-
-
OT302 EX DEVIATION SPEED
-
-
OT307 OVER SPEED
-
-
OT309 OVERHEAT MAIN CIRCUIT
-
-
OT310 LOW VOLT INPUT POWER
-
-
OT311 OVERVOLT POW CIRCUIT
-
-
OT312 OVERCURRENT POW CIRCUIT
-
-
OT313 DATA MEMORY FAULT CPU
-
-
OT318 SUMCHECK ERROR PGM DATA
-
-
OT319 EX OFFSET CURRENT U
-
-
OT320 EX OFFSET CURRENT V
-
-
OT324 SERIAL TRANSFER ERROR
-
-
OT325 SERIAL TRANSFER STOP
-
-
OT326 DISCONNECT C–VELO DETCT
-
-
OT327 DISCONNECT POS–CODER
-
-
OT328 DISCONNECT C–POS DETCT
-
-
OT329 OVERLOAD
-
-
OT330 OVERCURRENT POW CIRCUIT
-
-
OT331 MOTOR LOCK OR V–SIG LOS
-
-
OT332 RAM FAULT SERIAL LSI
-
-
OT333 SHORTAGE POWER CHARGE
-
-
OT334 PARAMETER SETTING ERROR
-
-
OT335 EX SETTING GEAR RATIO
-
-
OT336 OVERFLOW ERROR COUNTER
-
-
OT399 S–SPINDLE ERROR
-
-
OT512 EXCESS VELOCITY
-
-
OT513 SYNC EXCESS ERROR
File Access Alarm (IO ALARM)
-
IO030 CHECK SUM ERROR
-
-
IO031 INVALID CODE
-
-
IO032 MEMORY ACCESS OVER RANGE
Power Mmust Be Turned Off Alarm (PW ALARM)
-
PW000 POWER MUST BE OFF
-
-
PW100 ILLEGAL PARAMETER (S–COMP.)
Overheat Alarm (OH ALARM)
-
OH000 MOTOR OVERHEAT
-
-
OH001 LOCKER OVERHEAT
PC Errors
-
PC010 PC ERROR
-
-
PC020 PC ERROR
-
-
PC030 PC ERROR
-
-
PC500 WATCH DOG ALARM
Graphic RAM Parity
-
SB010 GRAPHIC RAM PARITY
-
-
SB011 GRAPHIC RAM PARITY (WORK)
-
-
SB011 GRAPHIC RAM PARITY (RED)
-
-
SB011 GRAPHIC RAM PARITY (GREEN)
-
-
SB011 GRAPHIC RAM PARITY (BLUE)