SV0034, SP9212 alarm on Fanuc 30iB control with Alpha i-B amplifiers (Fanuc Manual B-65285EN)
Alarm Code 24 (SV0034, SP9212)
(1) Meaning
The setting parameters for the Power Supply or the Power Supply are abnormal. Or, a submodule
that does not support the Power Supply (such as PFB-R or PFB-C) is connected.
(2) Cause and troubleshooting
(a) The setting parameters for the Power Supply are abnormal.
→ Set the parameters according to Chapter 15 in the FANUC SERVO AMPLIFIER αi-B series
DESCRIPTIONS (B-65412EN).
(b) The selected Power Supply and submodule cannot be used together.
→ Connect the Power Supply and submodule with the correct ordering numbers according to
Appendix I in the FANUC SERVO AMPLIFIER αi-B series DESCRIPTIONS (B-65412EN).
(c) Failure in the Power Supply
→ Replace the Power Supply.
SV0034, SP9212 (Fanuc Manual B-65285EN)
This alarm is applicable for the following units
A06B-6200-H003
αiPS 3-B
A06B-6200-H008 αiPS 7.5-B
A06B-6200-H011 αiPS 11-B
A06B-6200-H015 αiPS 15-B
A06B-6200-H026 αiPS 26-B
A06B-6200-H030 αiPS 30-B
A06B-6200-H037 αiPS 37-B
A06B-6200-H055 αiPS 55-B
A06B-6202-H003 αiPS 3-B
A06B-6202-H008 αiPS 7.5-B
A06B-6202-H011 αiPS 11-B
A06B-6202-H015 αiPS 15-B
A06B-6202-H026 αiPS 26-B
A06B-6202-H030 αiPS 30-B
A06B-6202-H037 αiPS 37-B
A06B-6202-H055 αiPS 55-B
© Copyright 2024 KFASLLC Houston, Texas, USA