KFAS: Fanuc CNC Parts, Service, & Repair
K Factory Automation Services has large inventory of Fanuc parts in stock and we maintain a full service in-house repair facility.
SV0432, SP9111 alarm on Fanuc 30iB control with Alpha i-B amplifiers (Fanuc Manual B-65285EN)
Alarm Code 06 (SV0432, SP9111)
(1) Meaning
The control power supply voltage decrease.
The 24 V power input to the connector (CXA2D) is abnormal. (Internal fuse blown)
(2) Cause and troubleshooting
(a) Abnormal condition of the power supply
→ The 24 V power input to the connector (CXA2D) is abnormal. Check the output voltage and
output capacity of the power supply.
(b) Failure in the Power Supply
→ Replace the Power Supply.
SV0432, SP9111 (Fanuc Manual B-65285EN)
This alarm is applicable for the following units
A06B-6200-H003
αiPS 3-B
A06B-6200-H008 αiPS 7.5-B
A06B-6200-H011 αiPS 11-B
A06B-6200-H015 αiPS 15-B
A06B-6200-H026 αiPS 26-B
A06B-6200-H030 αiPS 30-B
A06B-6200-H037 αiPS 37-B
A06B-6200-H055 αiPS 55-B
A06B-6202-H003 αiPS 3-B
A06B-6202-H008 αiPS 7.5-B
A06B-6202-H011 αiPS 11-B
A06B-6202-H015 αiPS 15-B
A06B-6202-H026 αiPS 26-B
A06B-6202-H030 αiPS 30-B
A06B-6202-H037 αiPS 37-B
A06B-6202-H055 αiPS 55-B
© Copyright 2024 KFASLLC Houston, Texas, USA