KFAS: Fanuc Parts & Repair

           

A06B-6117-H109 SVM-i 1-360i

a06b-6117-h109

Rated Input: 283-325VDC 26 kW

Rated Output Current: L axis   115 A

A06B6117H109 B65282E Manual

Related technical information

Understanding Cooling Fan Alarms

A06B-6117-H109 Alarms Meaning and action to be taken

Alarm     Meaning
1              Internal Fan Stopped (FAL)
2              Low control power voltage (LV5V)
5              Low DC link voltage (LVDC)
6              Inverter Overheat          Alarm "6" or "b"
F              External Cooling Fan Stop
P              Communication Error
8              L-axis over-current (HCL)
9              M-axis over-current (HCM)
A              N-axis over-current (HCN) 
b             L & M-axis over-current     Alarm "6" or "b"
C             M & N-axis over-current
d             L & N-axis over-current
E              L, M, N -axis over-current
8.             L-axis IPM alarm (IPML)
9.             M-axis IPM alarm (IPMM)
A.             N-axis IPM alarm (IPMN) 
b.            L & M-axis IPM alarm
C.            M & N-axis IPM alarm
d.            L & N-axis IPM alarm
E.             L, M, N-axis IPM alarm
L            FSSB Disconnect COP10A
U            FSSB Disconnect COP10B

A06B-6117-H109

Related Part Numbers
A20B-2100-0830
A16B-2203-0625
A20B-2101-0070
A16B-2203-0875

A90L-0001-0511
A90L-0001-0509