Rated Input: 283-325VDC 4.5 kW
Rated Output Current: L axis 13 A
A06B6114H104 B65282E Description Manual
A06B6114H104 B65285E Maintenance Manual
Understanding Cooling Fan Alarms
A06B-6114-H104 Alarms Meaning and action to be taken
Alarm Meaning
1
Internal Fan Stopped (FAL)
2
Low control power voltage (LV5V)
5
Low DC link voltage (LVDC)
6
Inverter Overheat Alarm
"6" or "b"
F
External Cooling Fan Stop
P
Communication Error
8
L-axis over-current (HCL)
9
M-axis over-current (HCM)
A
N-axis over-current (HCN)
b L
& M-axis over-current Alarm
"6" or "b"
C M
& N-axis over-current
d L
& N-axis over-current
E
L, M, N -axis over-current
8.
L-axis IPM alarm (IPML)
9.
M-axis IPM alarm (IPMM)
A.
N-axis IPM alarm (IPMN)
b. L
& M-axis IPM alarm
C. M
& N-axis IPM alarm
d. L
& N-axis IPM alarm
E.
L, M, N-axis IPM alarm
L
FSSB Disconnect COP10A
U
FSSB Disconnect COP10B
Related Part NumbersKFASLLC
kfasllc.com
A16B-2203-0660
A20B-2101-0040
A20B-2100-0740
A90L-0001-0510
Purchasing options for the FANUC A06B-6114-H104 Servo Amplifier Drive can be viewed in the details above. KFASLLC offers a wide selection of FANUC parts in new and refurbished condition.
If your FANUC A06B6114H104 drive needs to be repaired, we also offer 2 business days turnaround. Be sure to also check out our core credit exchange program for this and other products.
KFASLLC offers a huge variety of other FANUC CNC Drives and other FANUC parts in our online store.
Fanuc Alpha Servo A06B-6114-H104 features
・high power and high acceleration due to optimum winding design and
effective cooling structure.
・Increased torque at low speed range
・Super High precision and high resolution Alpha-iA pulse coder
feedback(16,000,000 pulses/rev)
・Available with both 200V input and 400V input
・Compact size with latest intelligent Power Module (IPM) technology.
・Utilize power source regeneration technology to return regeneration
energy of the motor to a power source.
Compared with the resistor regeneration, power consumption is largely reduced.