A06B-6112-H026#H550 SPM-26i

a06b-6111-H026-H550

$2,950 ($600 Exchange Credit Available)   

Repair/ Return Option Available At $1950.

Rated INPUT: 283-325VDC 29.8kW

 Rated OUTPUT: 230VAC  111A

A06B6112H026 B65282E Manual

Related technical information  View Picture

A06B-6112-H026 Alpha-i Spindle Amplifier Module uses internal cooling fan A90L-0001-0511 and external cooling fan A90L-0001-0509

A06B-6112-H026 Alarms Meaning 
Alarm     Description
0, 00    
Amplifier is ready (normal operating state)

1, 01    
Spindle motor over temp

2, 02    
Actual motor speed is deviated from the commanded speed.

3, 03    
DC link fuse has blown

4, 04    
Open phase detected in the 3-phase input to the the PSM.

6, 06    
Temperature sensor disconnected

7, 07    
Excessive speed

9, 09    
The heat sink of the SPM overheat.

11        
PSM detected that the DC link overvoltage

12        
DC link overcurrent

15        
Spindle switching operation sequence error.

18        
EPROM checksum error.

19        
U phase current detection error.

20        
V phase current detection error.

21        
Position sensor polarity setting incorrect

24        
Serial transfer data error (or The power to the CNC is turned off).

27        
Position coder signal disconnect.

29        
An excessive load

30        
Overcurrent in the PSM.

31        
Motor lock alarm.

32        
Serial communication LSI memory error.

33        
The PSM/DC Link charge error.

34        
Parameter data outof range.

36        
Error counter overflowed.

37        
Speed detector parameter error

41        
Position coder one-rotation signal detection error.

42        
Position coder one-rotation signal not detected.

46        
Position coder one-rotation signal detection error during thread cutting.

47        
Position coder signal error.

50        
Excessive speed command in spindle synchronization.

51        
PSM DC link undervoltage.

52        
The synchronization signal (ITP) error.

53        
The synchronization signal (ITP) error.

54        
Current overload alarm

55        
Abnormal spindle switching control.

56        
Internal cooling fan error.

58        
PSM internal temperature high.

59        
PSM internal cooling fan stopped.

66        
Communication alarm between spindle and SPM.

73        
Motor sensor is disconnected.

74        
SPM CPU alarm

75        
SPM CPU alarm

79        
Abnormal initial start up alarm

81        
Motor sensor one-rotation signal detection error.

82        
Motor sensor one-rotation signal not detected

83        
Motor sensor signal error

84        
Speed sensor disconnected.

85        
Spindle sensor one-rotation signal detection error.

86        
Spindle sensor one-rotation signal not detected.

87        
Spindle sensor signal error

88        
SPM External cooling error.

A, A1, A2    
SPM Program ROM error

b0        
Communication error between amplifier modules

C0, C1, C2    
Communication data error between the CNC and SPM.

A06B-6112-H026

A06B-6112-H026 is part of Fanuc Alpha-i Series family with advanced features including
High mechanical precision and low vibration making it possible to directly connect to the spindle achieving high mechanical precision and low vibration (V3).
Utilizes Power source regeneration technology to return regeneration energy of the motor to a power source. Compared with the resistor regeneration, power consumption is greatly reduced.
Compact, reduced Wiring utilizing fiber optics communications and easy maintenance features such as ability to replace cooling fans without disassembling the unit.
Center-through-coolant is available by direct connection with the spindle of a machining center. Air cooled αiIT series and oil cooled αiIL series are available.

Related Part NumbersKFASLLC kfasllc.com

A16B-2203-0621

A20B-2101-0355

A20B-2100-0801