KFAS: Fanuc Parts & Repair

       

A06B-6079-H206  SVM2-40/40

A06B-6079-H206

SAME DAY SHIPPING: IF ORDERED BY 3PM CENTRAL TIME

$1,250  ($300 Exchange Credit Available)    

Select Shipping Option
Your UPS Account# to collect

Repair/ Return Option Also Available At $780. 

Dimensions (H 380 x W 60 x D 307 mm)

Rated Input: 283-325VDC 5.3 kW

Rated Output Current: L axis 12.5A, M axis 12.5A

A06B6079H206 B65165E Manual

Related technical information

A06B-6079-H206 S1 S2 Jumper

A06B-6079-H206 Alarms Meaning and action to be taken

Alarm     Meaning
1              Internal Fan Stopped (FAL)
2              Low control power voltage (LV5V)
5              Low DC link voltage (LVDC)
8              L-axis over-current (HCL)
9              M-axis over-current (HCM)
A              N-axis over-current (HCN) 
b             L & M-axis over-current
C             M & N-axis over-current
d             L & N-axis over-current
E              L, M, N -axis over-current
8.             L-axis IPM alarm (IPML)
9.             M-axis IPM alarm (IPMM)
A.             N-axis IPM alarm (IPMN) 
b.            L & M-axis IPM alarm
C.            M & N-axis IPM alarm
d.            L & N-axis IPM alarm
E.             L, M, N-axis IPM alarm

A06B-6079-H206 is typically used with Fanuc 16TA, 16MA, 18TC, 18MC, 21TB, and 21MB controls. Typically A06B-6079-H206 is found on machines such as Fortune VT-26, Toshiba VTL TUE-20

Fanuc Servo Amplifier A06B-6079-H206 Alarm 8, Alarm 9, or Alarm A indicates high current or short circuit in the servo amplifier or motor.

Troubleshooting Steps for Alarm-8, Alarm-9, or Alarm-A
(1) Power off the machine. Remove the power line wires from the servo amplifier terminals, and be sure to place them so that there is no chance or shorting out something in the electrical cabinet. Power ON the machine/ control and release an emergency stop. If an abnormal current alarm occurs, go to (3). If not, go to (2). 

(2) Check for insulation between PE and each of the removed power wires U, V, and W.  Good/ acceptable insulation is in the order of several HUNDRED MEGA OHMS or higher.  
If not, disconnect the power wires from the motor.  Then check for insulation again between PE and each of the U, V, and W terminals on the motor itself. If there is a short circuit between PE and  U, V, or W of the motor, replace the motor. If motor insulation is tested good, replace the motor power wires.

A06B-6079-H206 EA7604786
A06B-6079-H206 EA8127424

Related Part NumbersKFASLLC kfasllc.com

A50L-0001-0304
A230-0526-X001/B
A230-0527-X001/A
A230-0527-X002
A20B-2001-0931
A16B-2202-0772
or A16B-2203-0592
A90L-0001-0385 (40x40x20mm) or A90L-0001-0441 (40x40x15mm)

The FANUC A06B-6079-H206 Servo Amplifier Module is a dual axis Alpha Servo Drive Model SVM2-40/40. As part of the A06B-6079 series of AC Servo Drives, the FANUC A06B-6079-H206 is Type A interface and fitted on small to medium size CNC machines for 0M, OT, 15, 16, 18, and 21 series controls. The FANUC A06B6079H206 amplifier powers with a rated input of 283-325V (5.3kW), a maximum output voltage of 230V, and a rated output current of 12.5A on the L axis and M axis. For repair options, contact our free tech support by. Make sure to specify if you are using one or two CX5 battery ports when you submit your inquiry. Read the details above for core credit exchange and purchasing options. The FANUC A06B-6079-H206 Servo Amplifier Module is part of our large online inventory of FANUC drives, controls, and other FANUC parts.

© Copyright KFASLLC Houston, Texas, USA