KFAS: Fanuc Parts & Repair 

       

A06B-6110-H011  PSM-11i

SAME DAY SHIPPING: IF ORDERED BY 3PM CENTRAL TIME

A06B-6110-H011

$1,975 ($650 Exchange Credit Available)   

Repair Fee: $1355

Select Desire Shipping Option
Your UPS Account#

Repair/ Return Option Available At $1100

Rated INPUT: 200-230VAC  49A@200V  50Hz/60Hz  3-phase

 Rated OUTPUT: 283-325VDC  13.2kW

A06B6110H011 B65282E Manual

Related technical information  Connection Info

 A06B-6110-H011 Alpha-i Power Supply Module uses internal cooling fan A90L-0001-0441 and external cooling fan A90L-0001-0508

A06B-6110-H011 Alarms Meaning and action to be taken
AL-1 : Overcurrent in the Main Power Module.
AL-2 : Cooling Fan Stopped.
AL-3 : The temperature of the main circuit heat sink has risen abnormally.
AL-4 : The DC Voltage has dropped.
AL-5 : The main Capacitor was not recharged within the specified time.
AL-6 : The Input Power Supply is Abnormal.
AL-7 : In the main circuit the DC Voltage is abnormally high.
AL-A : External cooling fan (located on heat sink) has stopped
AL-E : The Input Power Supply is Abnormal (open phase)

a06b6110h011

Related Part NumbersKFASLLC kfasllc.com

A20B-2100-0761

A20B-2100-0762

A20B-2100-0392

A16B-2203-0641