A06B-6102-H211 SPM-11
A06B-6102-H211#H520 A06B-6102-H211#H502
SAME DAY SHIPPING: IF ORDERED BY 3PM CENTRAL TIME
$2,200 ($600 Exchange Credit Available)
Rated INPUT: 283-325VDC 13.2kW
Maximum OUTPUT: 230VAC 48A
Spindle Amplifier Module A06B-6102-H211#H520 or A06B-6102-H211#H520 is used with spindle motor Alpha6, Alpha8, AlphaP8 and AlphaP12
Related technical information View Picture
A06B-6102-H211 Alarms Meaning and action to be taken
Alarm
Fault
– Not Ready(Not an alarm)
0
Control Ready(Not an alarm)
1 Motor overheat
2 Excessive Speed Error
3 Fuse on DC Link Blown(SPM is faulty)
4 Input Fuse/Power Fault(PSM is faulty)
5 Power Supply Fuse Blown
7 Overspeed
8 High Voltage Power Input
9 Overheat Main CIrcuit(SPM is faulty)
10 Low Voltage Input Power(Check input power)
11 Overvoltage in Power Circuit(PSM is faulty)
12 Overcurrent in Power Circuit
13 Data Memory Fault CPU(SPM is faulty)
15 SP Switch Control Alarm
16 RAM Fault(SPM is faulty)
18 CheckSum Error PGM Data
19 EX Offset Current U
20 EX Offset Current V
24 Serial Transfer Error(normal
if CNC is OFF)
25 Serial Transfer Stop
26 Disconnect C Velocity Detect
27 Pulsecoder Disconnected
28 Disconnect C-Pos Detect
29 Short time overload
30 Overcurrent(PSM is faulty)
31 Motor Lock or V-Sig Lost
32 Ram Fault Serial LSI
33 Shortage Power Charge(PSM is faulty)
34 Parameter Setting Error
35 Ex Setting Gear Ratio
36 Overflow Error Counter
37 Speed Detect Par. Error
39 1-Rot Cs Signal Detect
40 No 1 Rot Cs Signal Detect
41 1-Rot Position Coder Error
42 No 1 Rot. Position Coder Detect
43 Disconnect PC for Dif SP Mod
44 Control Circuit (AD) Error
46 Screw 1-Rot Position Coder Alarm
47 Position Coder Signal Abnormal
49 High Conv. Diff. Speed
50 Spindle Control Over Speed
51 Low Voltage DC Link(PSM is faulty)
52 ITP Signal Abnormal 1
53 ITP Signal Abnormal 2
56 Inner Cooling Fan Stop
57 Ex Deceleration Power
58 Overload in PSM(PSM is faulty)
59 Cooling Fan Stopped in PSM(PSM is faulty)
66 Communication Alarm between Spindle and Amplifier
69 Safety Speed Exceeded
70 Abnormal Axis Data
71 Abnormal Safety Parameter
72 Motor Speed Mismatch
73 Motor Sensor Disconnected
74 CPU Test Alarm
75 CRC Test Alarm
76 Safety Function Not Executed
77 Axis Number Mismatch
78 Safety Parameter Mismatch
79 Abnormal Initial Test Operation
81 Motor Sensor one-rotation signal detection error
82 Motor Sensor one-rotation signal not detected
83 Motor Sensor Signal Error
84 Spindle Sensor Disconnected
85 Spindle Sensor one-rotation signal detection error
86 Spindle Sensor one-rotation signal not detected
87 Spindle Sensor Signal Error
88 Cooling Fan on the radiator stopped(SPM is faulty)
A06B-6102-H211#H520 is typically used with Fanuc 16iTA, 16iMA, 18iTA, 18iMA,
21iTA, and 21iMA controls.
Typically found on machines such as Mori Seiki
MV-40E, Hakisui HTL-80, Youji YV1200
A06B-6102-H211 Alarm 12 and Alarm 03 Troubleshooting Steps
(1) Power off the machine. Remove the power line wires from the spindle amplifier terminals, and be sure to place them so that there is no chance or shorting out something in the electrical cabinet. Power ON the machine/ control and command the spindle.
If Alarm 12 occurs, go to (3). If not, go to (2).
(2) Check for insulation between PE and each of the removed power wires U, V, and W. Good/ acceptable insulation is in the order of several HUNDRED MEGA OHMS or higher.
If not, disconnect the power wires from the motor. Then check for insulation again between PE and each of the U, V, and W terminals on the motor itself. If there is a short circuit between PE and U, V, or W of the motor, replace the motor.
If motor insulation is tested good, replace the motor power wires.
Related Part NumbersKFASLLC kfasllc.com
A06B-6102-H211#H520 or A06B-6102-H211#H520 is equipped with the internal cooling fan A90L-0001-0423
Description