Rated INPUT: 200V-230VAC 49A@200V 50Hz/60Hz 3-phase
Rated OUTPUT: 283-325VDC 13.2kW
Related technical information Technical Info
A06B-6077-H111 Alarms Meaning and action to be taken
AL-01 :
Overcurrent in the Main Power Module.
AL-02 :
Cooling Fan Stopped.
AL-03 :
The temperature of the main circuit heat sink has risen abnormally.
AL-04 :
The DC Voltage has dropped.
AL-05 :
The main Capacitor was not recharged within the specified time.
AL-06 :
The Input Power Supply is Abnormal.
AL-07 :
In the main circuit the DC Voltage is abnormally high.
A06B-6077-H111 is typically used with Fanuc 16iTA, 16iMA, 18iTA, 18iMA, 21iTA, and 21iMA controls. Typically found on machines such as Mori Seiki MV-40E, Hakisui HTL-80, Fortune VT-26