KFAS: Fanuc Parts & Repair 

       

A06B-6110-H030  PSM-30i

SAME DAY SHIPPING: IF ORDERED BY 3PM CENTRAL TIME

A06B-6110-H030

$2,700 ($700 Exchange Credit Available)   

Repair Fee: $1550

Select Desire Shipping Option
Your UPS Account# TO COLLECT

Rated INPUT: 200-230VAC  127A@200V  50Hz/60Hz  3-phase

 Rated OUTPUT: 283-325VDC  35kW

A06B6110H030 B65282E Manual

Related technical information  Connector Info

 A06B-6110-H030 Alpha-i Power Supply Module uses internal cooling fan A90L-0001-0441#39 and external cooling fan A90L-0001-0509

A06B-6110-H030 Alarms Meaning and action to be taken
AL-1 : Overcurrent in the Main Power Module.
AL-2 : Cooling Fan Stopped.
AL-3 : The temperature of the main circuit heat sink has risen abnormally.
AL-4 : The DC Voltage has dropped.
AL-5 : The main Capacitor was not recharged within the specified time.
AL-6 : The Input Power Supply is Abnormal.
AL-7 : In the main circuit the DC Voltage is abnormally high.
AL-A : External cooling fan (located on heat sink) has stopped
AL-E : The Input Power Supply is Abnormal (open phase)

A06B-6110-H030 V04522646

Related Part NumbersKFASLLC kfasllc.com

A20B-2100-0761

A20B-2100-0762

A20B-2101-0392

A16B-2203-0631  

A06B-6110-H030 is part of Fanuc Alpha-i Series family with advanced features including
Utilizes Power source regeneration technology to return regeneration energy of the motor to a power source. Compared with the resistor regeneration, power consumption is greatly reduced.
Compact, reduced Wiring utilizing fiber optics communications and easy maintenance features such as ability to replace cooling fans without disassembling the unit.